One shell to rule them all, one shell to find them, one shell to bring them all and in the same distro bind them. This guide will help you get up and running with hps command line array configuration utility acu on ubuntu. I have a hp proliant server that is using hardware raid for the boot disk but when i used hpacucli no status was shown. Some software requires a valid warranty, current hewlett packard enterprise support contract, or a license fee. Please find list of useful commands for hpacucli for linux.
This website to share our expertise and knowledge on linux, unix, windows, hardware, security, cloud and open source. The command create will instruct hpacucli to create a new raid. This document shows some of the common used commands on hpacucli utility on linux. Create hardware raid on hp via hpacucli experiencing technology. To discover the model of the hard drive that is in an hp smart array, type the following command. Please terminate the acu application before running the acu cli. Im not at the machine right now, but basically i want to find out what the state of each of the physical disks in my server, i. To use hpacucli, download and install the latest version of hpacucli rpm from the hp website on your linux server. I have faced this issue to run the hpacucli and any described command worked. Hp array configuration utility command line interface for. How to use hp management command line interface by milosz galazka on february 20, 2017 and tagged with software recommendation, hardware hp management command line interface hpasmcli provides several useful and easily scriptable commands for hp proliant servers running linux.
How to run array diagnostic utility adu or hp insight diagnostics hp insight diagnostics to collect array status data or logs fro an esxi server how to. Linux is user friendly its just picky about which friends. Hpacucli or hp array configuration utility is the tool to use when it comes to hp array controllers on hp servers. Linux hpacucli this document is a quick cheat sheet on how to use the hpacucli utility to add, delete, identify and repair logical and physical disks on the smart array 5i plus controller, the server that these commands were tested on was a hp dl380 g3 server with a smart array 5i plus controller. Install hp command line array configuration utility 7. Today i am one of the operations center day duty and part of my task is to attend to alarms it is both passive and reactive mode. Hp array configuration utility command cheat sheet. Home hardware hpux linux unix hpacucli commands referrence. Linux shell or terminal so, basically, a shell is a program that receives commands from the user and gives it to the os to process, and it shows the output. Hp array configuration utility command line interface for integrity linux environments support notes version 7. This guide may will be especially useful if you have an hp proliant server, or an hp p400 \ p410 raid card or similar. Either run commands to get output that can be feed to monitoring scripts.
Hpacucli stands for hp array configuration utility cli. Hp smart array cli commands these should apply to any system with the cli installed. I dont want to steal any credit from its original authors, but i do think it should be reposted for archival. The raid i will create on those disks will be a raid 5. Hpe smart array cli commands on esxi kalles playground. In order to install the hp array controller cli on debian wheezy you must connect with putty or login to the terminal on the desired debian server. Lazysystemadmin is a useful howto website that covers system administration, operating systems, cloud, devops, virtualization, scripts and video tutorials. Login with root user id to run the following examples.
The command contains as usual the command controller and the slot of the controller. By joining our community you will have the ability to post topics, receive our newsletter, use the advanced search, subscribe to threads and access many other special features. I needed to expand an array on a vmware virtual host server but didnt want the downtime to reboot and run the hp ssa gui. Installation of hp array configuration utility cli for. Type hpacucli help or type help at the cli prompt for usage details. When you type the command hpacucli hpssacli, it will display a prompt as shown below where you can enter all the hpacucli commands. Hp acucli, available as a part of the hp integrity essentials foundation pack for linux, is a command line disk configuration tool used to configure and manage hp smart array controllers and raid array controllers. Hp array configuration utility cli for linux hpacucli is a useful tool that allows you to manage your hp raid controller from command line via ssh, that is.
Home ubuntu configuring an hp array using the cli command line. The array configuration utility cli is a commandline based disk configuration program for smart array controllers and raid array. Hp array configuration utility cli hpacucli command. Linux distributions can leverage an extensive range of commands to accomplish various tasks. This document is a quick cheat sheet on how to use the hpacucli utility to add, delete, identify and repair logical and physical disks on the smart array 5i plus controller, the server that these commands were tested on was a hp dl380 g3 server with a smart array 5i plus controller with 6 x 72gb hot swappable disks, the server had oracle enterprise linux oel installed. Hp array configuration utility cli hpacucli for linux.
Get more information on hpacucli and check out how to configure sour raid and smart array controller on linux simply through command line. Description the hp array configuration utility command line interface hp acucli is a command linebased disk configuration tool that can be used to configure and. Create hardware raid on hp via hpacucli experiencing. Storage management on hp servers through command line. Another instance of acu is already running possibly a service. As the name suggests, this utility is for hp servers. On linux machines, the tool can be installed by getting the rpm from the hp site. I have down load this file hpacucli and copy to esxi data store. Theres a vib for it but it was already installed in my hp server esxi shell. Hp smart array cli commands these should apply to any system with the cli installed show configuration opthphpssaclibinhpssacli ctrl all show config.
Command line is one of the many strengths of linux based systems. It can also be used to monitor the state of the disk subsystem with tools like nagios or zabbix. Installing hp array configuration utility hp acu on. How to run the hp online acu cli for linux in esxi 4. Linux acucliarray configuration utility command linux interface. Configuring a new hardware raid on a hp server can be done comfortably from the linux command line without restarting the server. Hp array configuration utility cli for linux 64bit. The ultimate a to z list of linux commands linux command. Has anyone used the hp array configuration utility command line interface hpacucli. Did you know that you can control your hp controller through command line. How to use hp command line array configuration utility. Whenever there is a requirement to increase the disk size in your local disk on the server, it is really very helpful to create a disk using hpacucli via command. Install the npartition management gui for hp integrity servers. The tools helps configure all the specifics and parameters related to the array controller of the server.
Install hp system management homepage for linux on the itanium processor 3. Its distros come in gui graphical user interface, but basically, linux has a cli command line interface. Basic linux commands for beginners linux maker pro. For most linux distros, bash bourne again shell is the default command. By downloading, you agree to the terms and conditions of the hewlett packard enterprise software license agreement. Next you will run the commands below to add the debian hpproliant repository to your system and install hpacucli. Hpacucli is used to create, delete and repair the logical and physical drives on the smart array controllers in hp servers. Me too, so i did some googling and found an awesome cheat sheet. Hp command line array configuration utility hpacucli provides several. Most of these commands are used to perform maintenance on the hard disk connected to hp array.